    Lactate SCOUT Sport

    The compact Lactate SCOUT Sport from EKF is used for the determination of lactate in fresh capillary blood samples using an enzymatic-amperometric method, allowing changes in the physical performance and conditions of athletes to be evaluated. It provides reliable measurement results in just 10 seconds and is operated simply and intuitively thanks to its 4-button design. The user can perform individual or stage tests as needed, and there is a handy stopwatch function. Stage measurements include resting value, main load and recovery.


    Since the device features a Bluetooth LE module, the collected data can be transferred wirelessly to an external PC with the Lactate SCOUT Assistant analysis software. It is also possible to pair the lactate measuring device with a Bluetooth-compatible heart rate monitor. In addition, the lactate meter compensates for the influence of low or high hematocrit values ​​on the lactate measurement results. The integrated memory can store up to 500 measurement results, which are documented with date and time. On the large electronic ink display (E-Paper), even in difficult lighting conditions, the lactate value, date and time, measurement mode, temperature, heart rate and memory identification can be read.


    Product Details

    • Lactate SCOUT Sport by EKF diagnostics 

    • Compact and precise manual measuring device

    • For the enzymatic-amperometric determination of lactate

    • Quick results in just 10 seconds

    • Simple and intuitive operation using 4 buttons

    • Large electronic E Paper display for better readability

    • Sample material: capillary blood

    • Small sample volume of only 0.2 µl

    • Measuring range: 0.5 - 25 mmol/L

    • Allows single or step measurements

    • Step tests consisting of rest, main load and recovery values

    • Equipped with a practical stopwatch function

    • Compatible with Lactate SCOUT pre-calibrated test strips

    • Compensates for the influence of low/high hematocrit levels

    • Perform regular automatic self-tests

    • Independent control solutions available in different concentrations

    • Can connect to Bluetooth compatible heart rate monitors

    • Lactate SCOUT Assistant evaluation software included in starter kit

    • To evaluate changes in performance and physical condition

    • Battery operation, 2 CR2450 batteries enough for up to 1,000 measurements

    • Wireless transmission of collected data via Bluetooth to an external PC

    • Compatible with Android and iOS devices

    • Integrated memory for up to 500 measurements with date and time

    • Supplied with 2 CR-2450 button batteries

    • Available as an individual device or in a starter set


    Technical specifications

    Indication on screen

    Lactate measurement value, date/time, measurement mode, temperature, heart rate, memory ID

    Sample type

    fresh capillary blood

    Number of samples

    0.2 μl

    Measuring range

    0.5 mmol/l - 25.0 mmol/l

    Reference system

    Biosen C-Line (EKF diagnostics)

    Hematocrit range (Hct)

    20-70%

    Measuring principle

    Enzymatic-amperometric determination of lactate by lactate oxidase

    Tolerance to interfering substances

    Paracetamol up to 0.662 mmol/l

    Ascorbate up to 0.342 mmol/l

    Uric acid up to 0.550 mmol/l

    Reagent per test strip

    Lactate oxidase, electron mediators, additives

    Test duration

    10 seconds

    Temperature

    From +10 to +45 °C

    Air humidity

    10-85% relative humidity (max. 2 minutes for test strips)

    Storage temperature

    -18 to +8 °C (test strips), -20 to +50 °C (device)

    Max. Use altitude

    4,000 meters

    Data storage

    500 lactate measurement values ​​with date, time, heart rate and step test, heart rate memory for more than 30 hours

    Data transmission

    About Bluetooth LE v4.1

    Feeding

    2x 3V CR2450 (3V lithium button batteries)

    Dimensions (length x width x height)

    91 x 46 x 21mm

    Weight

    60g (batteries included)

    Content


    Variant

    Content

    Only

    - SCOUT Sport portable lactate meter

    - 2 CR2450 batteries

    - instruction manual

    Starter Kit

    - SCOUT Sport portable Lactate meter

    - 2 CR2450 batteries

    - Spray bottle

    - Instruction manual

    - Lactate SCOUT Assistant Software